-40%
US Seller Digital 12-lead ECG&EKG Machine electrocardiograph,PC software,FDA CE
$ 131.47
- Description
- Size Guide
Description
Model 1:ECG90A 12-channel 12 lead ECG with PC softwareIntroductions
ECG90A is an electrocardiograph collecting 12-lead ECG signal simultaneously and printing ECG waveform with thermal printing system, which features in, recording and displaying ECG waveform with manual or auto mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”,
optional interface languages(Chinese/English), case database management.
Function
1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Particular and high-accurate digital filter eliminates baseline drift, no distortion to ECG waveform, greatly enhances anti-baseline drift capacity, convenient for waveform judgment.
3)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
4)Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).
5)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz.
6)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
7)Optional SD card stores up to 100 cases, which is convenient for doctor to review case and statistic.
8)In review mode, case waveform stored can be checked, measurement parameter and diagnosis information can be automatically analyzed.
9)Two languages(Chinese or English) interface and report.
10)Optional ECG-Sync software, connect with PC by USB2.0 interface to form a ECG workstation, collect real-time data to the software for analyzing and printing the report, and old cases stored in Electrocardiograph can be uploaded to PC.
11)Power supply: AC/DC, and in optimal DC state, built-in rechargeable lithium battery can continuously work for 4-hour, print up to 90-minute and 150-ECG, which meets the requirements of visiting a patient at home and body examination. Rechargeable lithium battery is detachable, which is convenient for user to replace and charge in any time.
Performance
Input mode: floating and defibrillation protection
Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
CMRR: >60dB, >100dB(add filter)
Time constant:≥ 3.2s
Patient leak current: <10µA
Calibration voltage: 1mV
Sensitivity: 5, 10, 20 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
Noise level: ≤15µVp-p
Input circuit current: ≤50nA
Input impedance: ≥50MΩ
Sampling accuracy: 12-bit
Safety classification: class I, type CF and defibrillation-proof applied part
Recording mode: thermal printing system
Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
Paper size: 50mm(W)×20m(L)
Sampling frequency: 1000Hz
Polarizing voltage: ±500mV
EMG interference filter: 25Hz/35Hz (-3dB)
Power frequency filter: AC 50Hz/60Hz(-20dB)
Paper speed:
Auto: 6.25, 12.5, 25, 50mm/s, ±5%
Manual: 6.25, 12.5, 25, 50mm/s, ±5%
Power supply: DC 12V adapter, 7.4V/2000mAh rechargeable lithium battery
Waterproof degree: IPX0
Working mode: continuous working
Accessories
A lead cable
An electrode adapter
Disposable electrode
A thermal recording paper
A power cord
An earth wire
A user manual
A power adapter
ECG-Sync software+USB cable
SD card
Model 2:ECG100G one-channel 12-lead ECG without software
Introduction
ECG100G is a kind of single channel electrocardiograph, which features in printing ECG waveform by thermal printing system, prompting for "Lead off" or "Lack of paper", multi-language interface, recording ECG waveform in AUTO/Manual mode, convenient to operate.
Function
1)Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz.
3)Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).
4)In AUTO mode, finish recording by pressing the button once, which improves work efficiency.
5)Multi-language (Chinese, English, French, Italian, German, Spanish and Turkish) interface and report.
6)In optimal DC state, up to 7-hour standby time, continuous print up to 4-hour, record up to 150 ECG waveform.
Performance
Input mode: floating and defibrillation protection
Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
CMRR: >60dB, >100dB(add filter)
Time constant:≥ 3.2s
Patient leak current: <10µA
Calibration voltage: 1mV
Sensitivity: 5, 10, 20 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
Noise level: ≤15µVp-p
Input circuit current: ≤50nA
Input impedance: ≥50MΩ
Sampling accuracy: 12-bit
Safety classification: class I, type CF and defibrillation-proof applied part
Recording mode: thermal printing system
Paper size: 50mm(W)×20m(L)
Sampling frequency: 800Hz
EMG interference filter: 35Hz (-3dB)
Power frequency filter: AC 50Hz/60Hz(-20dB)
Paper speed: 25, 50mm/s, ±5%
Power supply:
AC: 100V~240V(50/60Hz)
DC: 7.4V/2000mAh rechargeable lithium battery
Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V
Waterproof degree: IPX0
Working mode: continuous working
Accessories
Standard:
A lead cable
A limb electrode
A chest electrode
A thermal recording paper
A power cord
An earth wire
A user manual
Certification
CE,FDA
Model 3:ECG300G 3-channel 12-LEAD with PC Software
Introduction
ECG300G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting any rhythm lead, case database management.
Function
1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
3)Multiply printing modes and formats, including manual, auto 4×3, auto 3×4+1, auto 3×4, auto 2×6+1, auto 2×6, auto 3-2+1, auto 3-2, auto 1×12+1, auto 1×12, rhythm 4, rhythm 3 and rhythm 2, etc. Waveform length printed can be adjusted, and with time print function, which meets different requirements.
4)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
5)Built-in memory stores up to 1000 cases, convenient for case review and statistic.
6)Multi-language(Chinese, English, Spanish, Turkish, Polish, Italian, French, German, Portuguese, Kazakstan, Russian, Ukrainian, Serbian and Slovenian) interface and report.
Performance
Input mode: floating and defibrillation protection
Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
CMRR: >60dB, >100dB(add filter)
Time constant:≥ 3.2s
Patient leak current: <10µA
Calibration voltage: 1mV
Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
Noise level: <15µVp-p
Input circuit current: ≤50nA
Input impedance: ≥50MΩ
Sampling accuracy: 12-bit
Safety classification: class I, type CF and defibrillation-proof applied part
Recording mode: thermal printing system
Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing.
Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing.
Manual record: set record according to record format, manually switching leads.
Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
Paper size: 80mm(W)×20m(L)
Sampling frequency: 1000Hz
EMG interference filter: 25Hz/35Hz (-3dB)
Power frequency filter: AC 50Hz/60Hz(-20dB)
Paper speed:
Auto: 25, 50mm/s, ±5%
Rhythm: 25, 50mm/s, ±5%
Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5%
Power supply:
AC: 100V~240V(50/60Hz)
DC: 7.4V/3500mAh rechargeable lithium battery
Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V
Waterproof degree: IPX0
Working mode: continuous working
Accessories
A lead cable
ECG electrode
A thermal recording paper
A power cord
An earth wire
A user manual
ECG-Sync software+USB cable
Physical characteristic
Dimension: 315mm(L) × 215mm(W) × 77mm(H)
Weigh: 1.6Kg
Model 4:ECG1200G touch 12-channel 12-lead with Software
Introduction
ECG1200G is an electrocardiograph which can collect 12-lead ECG signal simultaneously and print ECG waveform with thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting rhythm lead, printing the trend chart and histogram of P-R interval, case database management.
Function
1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
3)Multiply printing modes and formats, including auto 12x1, auto 6x2+1, auto 6x2+1_H, auto 6x2, auto 6x2_H, auto 3x4+1, auto 3x4+2, rhythm 12, rhythm 10, rhythm 8, rhythm 6, manual, etc. Trend chart and histogram of P-R interval can be printed, waveform length printed can be adjusted, and with time print function, which meets different requirements.
4)Paper speed: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s.
5)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
6)Built-in memory stores up to 1000 cases, convenient for case review and statistic.
7)Multi-language(Turkish, French, Chinese, English, German, Kazakstan, Polish, Portuguese, Russian, Slovenian, Spanish and Ukrainian) interface and report.
8)In optimal DC state, up to 10-hour standby time, continuous print more than 3-hour, record up to 300 ECG waveform(commonly, it is 3s case), which meets the requirements of visiting a patient at home and body examination.
Performance
Input mode: floating and defibrillation protection
Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
CMRR: >60dB, >100dB(add filter)
Time constant:≥ 3.2s
Patient leak current: <10µA
Calibration voltage: 1mV
Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
Noise level: ≤15µVp-p
Input circuit current: ≤50nA
Input impedance: ≥50MΩ
Sampling accuracy: 12-bit
Safety classification: class I, type CF and defibrillation-proof applied part
Recording mode: thermal printing system
Paper size: 210mm(W)×20m(L)
Sampling frequency: 1000Hz
EMG interference filter: 25Hz/35Hz (-3dB)
Power frequency filter: AC 50Hz/60Hz(-20dB)
Paper speed:
Auto: 25, 50mm/s, ±5%
Rhythm: 25, 50mm/s, ±5%
Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5%
Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing.
Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing.
Manual record: set record according to record format, manually switching leads.
Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
Power supply:
AC: 100V~240V(50/60Hz)
DC: 14.8V/3500mAh rechargeable lithium battery
Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V
Waterproof degree: IPX0
Working mode: continuous working
Accessories
Standard:
A lead cable
A limb electrode
A chest electrode
A thermal recording paper
A power cord
An earth wire
A user manual
Physical characteristic
Working environment
Temperature: 5℃~40℃
Relative humidity: 25%~95%(non-condensing)
Atmospheric pressure: 700hPa~1060hPa
Transport and storage environment
Temperature: -40℃~+55℃
Relative humidity: ≤95%
Atmospheric pressure: 500hPa~1060hPa
Dimension: 340mm(L) × 320mm(W) × 85mm(H)
Weigh: 3.2Kg
Payment
1.Paypal
2.Bank transfer
Shipping
1. For your earlier and safer to receive the item, please leave us your detail address and telephone number.
2. Your item will be sent via Air mail within 48 hours after payment is received. The shipping time is around 2-6 weeks.
US buyer 2-5 days delivery.
3. As the usual way, buyer is responsible for the duties, taxes or other VAT or extr
a
charges from the import countries.
4.All items will be shipped to buyer's PayPal address. Please confirm your PayPal address is correct before purchase.
International Buyers - Please Note:
* Import duties, taxes are not included in item price or shipping charges. These charges are buyer's responsibility.
* Please check with your country's customs office to determine what these additional cost will be prior to bidding/buying.
Terms of Sale
Buy Safe Product!
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.
The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE,TUV of Europe.The Fingertip Pulse
Oximeter that is FDA 510K Approved
Feedback
Please leave me a positive feedback if you are satisfied with our products, Your positive feedback will be appreciated,thank you.
If you have any problems, please contact us asap before you open a case and leave a negative feedback or ship the item back,
we promise we will give you a satisfied answer, thank you for your understanding!
Return - After service
We offer 60 days return policy. 100% satisfaction is our goal!
1.All items are brand new ,with 1 years warranty.
2.If you have a defective item, you want to return or discount. Please contact us within 2 days from you receive the item.
3.We will refund the money to you when we get the return items or replace item for you.
4. All return items must be returned with its original package and accessories.
About us
Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company.
At present there are more than 1200 employees in our company.Our product line covers a wide range of 13 categories.
Most of the domestic hospitals are our customers.Contec hopes to cooperate with international companies to supply more
innovative design and advanced technology products.We sincerely welcome you to become one of our global partners.
We are looking forward to establishing a successful business relationship with you.
Contact us
Vivian Zhang
Only English User Manual,Please contact us if you need other language manual.