-40%

CONTEC Digital 1/3/12-Channel 12-lead electrocardiograph ECG/EKG Machine, +PC SW

$ 131.47

Availability: 97 in stock
  • Country/Region of Manufacture: United States
  • Number of Leads: 12-lead
  • Refund will be given as: Money Back
  • Return shipping will be paid by: Buyer
  • All returns accepted: Returns Accepted
  • Number of Channels: 1,3,12
  • MPN: 69450401
  • ECG & EKG Machine Type: Electrocardiograph
  • Operation: Digital
  • Condition: New
  • Brand: CONTEC
  • Features: Printer
  • Item must be returned within: 60 Days
  • Restocking Fee: No

    Description

    Model 1:ECG90A one-channel 12 lead ECG with PC software
    Introduction
    ECG90A is an electrocardiograph collecting 12-lead ECG signal simultaneously and printing ECG waveform with thermal printing system, which features in, recording and displaying ECG waveform with manual or auto mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”,
    optional interface languages(Chinese/English), case database management.
    Function
    1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
    2)Particular and high-accurate digital filter eliminates baseline drift, no distortion to ECG waveform, greatly enhances anti-baseline drift capacity, convenient for waveform judgment.
    3)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
    4)Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).
    5)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz.
    6)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
    7)Optional SD card stores up to 100 cases, which is convenient for doctor to review case and statistic.
    8)In review mode, case waveform stored can be checked, measurement parameter and diagnosis information can be automatically analyzed.
    9)Two languages(Chinese or English) interface and report.
    10)Optional ECG-Sync software, connect with PC by USB2.0 interface to form a ECG workstation, collect real-time data to the software for analyzing and printing the report, and old cases stored in Electrocardiograph can be uploaded to PC.
    11)Power supply: AC/DC, and in optimal DC state, built-in rechargeable lithium battery can continuously work for 4-hour, print up to 90-minute and 150-ECG, which meets the requirements of visiting a patient at home and body examination. Rechargeable lithium battery is detachable, which is convenient for user to replace and charge in any time.
    Performance
    Input mode: floating and defibrillation protection
    Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
    CMRR: >60dB, >100dB(add filter)
    Time constant:≥ 3.2s
    Patient leak current: <10µA
    Calibration voltage: 1mV
    Sensitivity: 5, 10, 20 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
    Noise level: ≤15µVp-p
    Input circuit current: ≤50nA
    Input impedance: ≥50MΩ
    Sampling accuracy: 12-bit
    Safety classification: class I, type CF and defibrillation-proof applied part
    Recording mode: thermal printing system
    Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
    Paper size: 50mm(W)×20m(L)
    Sampling frequency: 1000Hz
    Polarizing voltage: ±500mV
    EMG interference filter: 25Hz/35Hz (-3dB)
    Power frequency filter: AC 50Hz/60Hz(-20dB)
    Paper speed:
    Auto: 6.25, 12.5, 25, 50mm/s, ±5%
    Manual: 6.25, 12.5, 25, 50mm/s, ±5%
    Power supply: DC 12V adapter, 7.4V/2000mAh rechargeable lithium battery
    Waterproof degree: IPX0
    Working mode: continuous working
    Accessories
    A lead cable
    A limb electrode
    A chest electrode
    A thermal recording paper
    A power cord
    An earth wire
    A user manual
    A power adapter
    ECG-Sync software+USB cable
    SD card
    Physical characteristic
    Working environment
    Temperature: 5℃~40℃
    Relative humidity: 25%~95%(non-condensing)
    Atmospheric pressure: 700hPa~1060hPa
    Transport and storage environment
    Temperature: -40℃~+55℃
    Relative humidity: ≤95%
    Atmospheric pressure: 500hPa~1060hPa
    Dimension: 207mm(L) × 96mm(W) × 62mm(H)
    Weigh: 0.5Kg
    Model 2:
    ECG100G
    one-channel 12-lead ECG
    without software(No interpretaion)
    Introduction
    ECG100G is a kind of single channel electrocardiograph, which features in printing ECG waveform by thermal printing system, prompting for "Lead off" or "Lack of paper", multi-language interface, recording ECG waveform in AUTO/Manual mode, convenient to operate.
    Function
    1)Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
    2)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz.
    3)Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).
    4)In AUTO mode, finish recording by pressing the button once, which improves work efficiency.
    5)Multi-language (Chinese, English, French, Italian, German, Spanish and Turkish) interface and report.
    6)In optimal DC state, up to 7-hour standby time, continuous print up to 4-hour, record up to 150 ECG waveform.
    Performance
    Input mode: floating and defibrillation protection
    Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
    CMRR: >60dB, >100dB(add filter)
    Time constant:≥ 3.2s
    Patient leak current: <10µA
    Calibration voltage: 1mV
    Sensitivity: 5, 10, 20 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
    Noise level: ≤15µVp-p
    Input circuit current: ≤50nA
    Input impedance: ≥50MΩ
    Sampling accuracy: 12-bit
    Safety classification: class I, type CF and defibrillation-proof applied part
    Recording mode: thermal printing system
    Paper size: 50mm(W)×20m(L)
    Sampling frequency: 800Hz
    EMG interference filter: 35Hz (-3dB)
    Power frequency filter: AC 50Hz/60Hz(-20dB)
    Paper speed: 25, 50mm/s, ±5%
    Power supply:
    AC: 100V~240V(50/60Hz)
    DC: 7.4V/2000mAh rechargeable lithium battery
    Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V
    Waterproof degree: IPX0
    Working mode: continuous working
    Accessories
    Standard:
    A lead cable
    A limb electrode
    A chest electrode
    A thermal recording paper
    A power cord
    An earth wire
    A user manual
    Certification
    CE,FDA
    Model 3:ECG300G 3-channel 12-LEAD with PC Software
    Introduction
    ECG300G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting any rhythm lead, case database management.
    Function
    1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
    2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
    3)Multiply printing modes and formats, including manual, auto 4×3, auto 3×4+1, auto 3×4, auto 2×6+1, auto 2×6, auto 3-2+1, auto 3-2, auto 1×12+1, auto 1×12, rhythm 4, rhythm 3 and rhythm 2, etc. Waveform length printed can be adjusted, and with time print function, which meets different requirements.
    4)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
    5)Built-in memory stores up to 1000 cases, convenient for case review and statistic.
    6)Multi-language(Chinese, English, Spanish, Turkish, Polish, Italian, French, German, Portuguese, Kazakstan, Russian, Ukrainian, Serbian and Slovenian) interface and report.
    Performance
    Input mode: floating and defibrillation protection
    Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
    CMRR: >60dB, >100dB(add filter)
    Time constant:≥ 3.2s
    Patient leak current: <10µA
    Calibration voltage: 1mV
    Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
    Noise level: <15µVp-p
    Input circuit current: ≤50nA
    Input impedance: ≥50MΩ
    Sampling accuracy: 12-bit
    Safety classification: class I, type CF and defibrillation-proof applied part
    Recording mode: thermal printing system
    Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing.
    Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing.
    Manual record: set record according to record format, manually switching leads.
    Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
    Paper size: 80mm(W)×20m(L)
    Sampling frequency: 1000Hz
    EMG interference filter: 25Hz/35Hz (-3dB)
    Power frequency filter: AC 50Hz/60Hz(-20dB)
    Paper speed:
    Auto: 25, 50mm/s, ±5%
    Rhythm: 25, 50mm/s, ±5%
    Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5%
    Power supply:
    AC: 100V~240V(50/60Hz)
    DC: 7.4V/3500mAh rechargeable lithium battery
    Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V
    Waterproof degree: IPX0
    Working mode: continuous working
    Accessories
    A lead cable
    ECG electrode
    A thermal recording paper
    A power cord
    An earth wire
    A user manual
    ECG-Sync software+USB cable
    Physical characteristic
    Dimension: 315mm(L) × 215mm(W) × 77mm(H)
    Weigh: 1.6Kg
    Model 4:ECG1200G touch 12-channel 12-lead with Software
    Introduction
    ECG1200G is an electrocardiograph which can collect 12-lead ECG signal simultaneously and print ECG waveform with thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting rhythm lead, printing the trend chart and histogram of P-R interval, case database management.
    Function
    1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
    2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
    3)Multiply printing modes and formats, including auto 12x1, auto 6x2+1, auto 6x2+1_H, auto 6x2, auto 6x2_H, auto 3x4+1, auto 3x4+2, rhythm 12, rhythm 10, rhythm 8, rhythm 6, manual, etc. Trend chart and histogram of P-R interval can be printed, waveform length printed can be adjusted, and with time print function, which meets different requirements.
    4)Paper speed: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s.
    5)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
    6)Built-in memory stores up to 1000 cases, convenient for case review and statistic.
    7)Multi-language(Turkish, French, Chinese, English, German, Kazakstan, Polish, Portuguese, Russian, Slovenian, Spanish and Ukrainian) interface and report.
    8)In optimal DC state, up to 10-hour standby time, continuous print more than 3-hour, record up to 300 ECG waveform(commonly, it is 3s case), which meets the requirements of visiting a patient at home and body examination.
    Performance
    Input mode: floating and defibrillation protection
    Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
    CMRR: >60dB, >100dB(add filter)
    Time constant:≥ 3.2s
    Patient leak current: <10µA
    Calibration voltage: 1mV
    Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
    Noise level: ≤15µVp-p
    Input circuit current: ≤50nA
    Input impedance: ≥50MΩ
    Sampling accuracy: 12-bit
    Safety classification: class I, type CF and defibrillation-proof applied part
    Recording mode: thermal printing system
    Paper size: 210mm(W)×20m(L)
    Sampling frequency: 1000Hz
    EMG interference filter: 25Hz/35Hz (-3dB)
    Power frequency filter: AC 50Hz/60Hz(-20dB)
    Paper speed:
    Auto: 25, 50mm/s, ±5%
    Rhythm: 25, 50mm/s, ±5%
    Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5%
    Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing.
    Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing.
    Manual record: set record according to record format, manually switching leads.
    Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
    Power supply:
    AC: 100V~240V(50/60Hz)
    DC: 14.8V/3500mAh rechargeable lithium battery
    Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V
    Waterproof degree: IPX0
    Working mode: continuous working
    Accessories
    Standard:
    A lead cable
    A limb electrode
    A chest electrode
    A thermal recording paper
    A power cord
    An earth wire
    A user manual
    Physical characteristic
    Working environment
    Temperature: 5℃~40℃
    Relative humidity: 25%~95%(non-condensing)
    Atmospheric pressure: 700hPa~1060hPa
    Transport and storage environment
    Temperature: -40℃~+55℃
    Relative humidity: ≤95%
    Atmospheric pressure: 500hPa~1060hPa
    Dimension: 340mm(L) × 320mm(W) × 85mm(H)
    Weigh: 3.2Kg
    Buy safe Products
    The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies.If the item is subject to FDA regulation,
    We will verify your status as an authorized purchaser of this item before shipping of the item.If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health.
    The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE,TUV of Europe.The  Fingertip Pulse Oximeter that is FDA 510K Approved
    Shipping:
    * Clearance: we will ship your item(s) to your PayPal confirmed address.Please leave me your clear address,telephone,postal code.
    * It is the buyers' responsibility to consider duties, taxes and other extra charges by the government in your respective country.
    * All items will be dispatched within 2 business day,ship from China warehouse by Air mail 10-30 working days arrival.To US buyer,ship by FEDEX 2-6 work days arrival.
    * The item will be declared as lower value for shipping only.We'd like to cooperate with you and declare the value of it as you want us to, so that it is more easier for you to clear the custom.
    Return - After service
    We offer 60 days return policy. 100% satisfaction is our goal!
    1.All items are brand new ,with 1 years warranty.
    2.If you have a defective item, you want to return or discount. Please contact us within 2 days from you receive the shipment.
    3.We will refund the money to you when we get the return items or replace item for you.
    4. All return items must be returned with it's original packaging and accessories. Customer is responsible for shipping charges on returned items.
    Only English User manual,Please contact us if you need other language version.